Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Year range
1.
Article in Portuguese | LILACS | ID: lil-583322

ABSTRACT

Introdução: A limitação da amplitude de movimento de dorsiflexão é o parâmetro mais utilizado na avaliação e evolução da abordagem fisioterapêutica. Objetivos: Avaliar a confiabilidade e aplicabilidade da goniometria e do teste Weight-Bearing para a mensuração de dorsiflexão do tornozelo. Método: Participaram 25 voluntários, do sexo masculino, com idade média de 38,81 (± 6,26), distribuídos em dois grupos: G1 (n=13 Não-atleta) e G2 (n=12 Atletas). A medida da dorsiflexão do tornozelo foi realizada com goniômetro universal adaptado com haste metálica de 45 cm e por meio do teste Weigth-Bearing. Os dois métodos foram aplicados nos participantes por três examinadores, cada um efetuando a mensuração seis vezes. Com o ICC, verificou-se a confiabilidade dos testes. Resultados: Obtiveram-se ICC de 0,98 na goniometria, para o G1, e 0,97, para o G2. Já para o Weight-Bearing, obteve-se ICC de 0,98 para o G1 e o mesmo para o G2. Todas essas medidas foram consideradas muito elevadas. Conclusão: Ambos os métodos são de alta confiabilidade para aplicação clínica nessas condições experimentais.


Introduction: The limitation of the dorsiflexion movement range is the most used parameter in evaluation and evolution of physiotherapeutic approach. Objective: To evaluate the inter-tester reliability and the applicability of goniometry and Weight-Bearing test for measuring the ankle dorsiflexion. Method: Twenty five volunteers, male sex, average aged 38.81 (+6.26), were included in the study and distributed in: G1 (13 non-athletes) and G2 (12 athletes). The measurement of the ankle dorsiflexion was made by using a universal goniometer, which was adapted with a 45 cm metal rod, and also by using the Weight-Bearing test. The two methods were applied in all the participants, by three clinical examiners, each of whom made the measurement six times. The ICC was used to verify the reliability of the tests. Results: In goniometry, the ICC was 0.98 for G1 and 0.97 for G2. When it comes to Weight-Bearing, the ICC was 0.98 for G1 and the same for G2. All these measures were considered high values. Conclusion: As a conclusion, it may be said that both methods are of great reliability for clinical application in these experimental conditions.


Subject(s)
Humans , Male , Adult , Middle Aged , Arthrometry, Articular/methods , Resistance Training/methods , Arthrometry, Articular/instrumentation , Resistance Training/instrumentation , Athletes , Ankle
SELECTION OF CITATIONS
SEARCH DETAIL